    SCOPE

    This specification includes 40C10T/R-1 ultrasonic sensor size, characteristics, performance parameters and precautions, before using this product, please read this specification. 40C10T-1 is the transmitter, 40C10R-1 is the receiver.It generally can be used for ultrasonic range finder, ultrasonic sensor for non-contact detect objects, ultrasonic distance sensor, ultrasonic automation control, etc. If you have any questions for other applications, please contact us for details.

    OUTLINE DIMENSION


    CHARACTERISTICS

    Part Number

    40C10T-1

    40C10R-1

    Construction

    Open structure type

    Open structure type

    Using Method

    Transmitter

    Receiver

    Nominal Frequency

    40.0±1.0KHz

    40.0±1.0KHz

    Sound Pressure

    100dB min

    --

    Sensitivity

    --

    -70dB min.

    Capacitance

    1600Pf±20%

    1600Pf±20%

    Max. Input Voltage

    40Vp-p

    40Vp-p

    Directivity

    80°±15°(-6dB)

    80°±15°(-6dB)

    Distance of Detection

    0.2~10m

    0.2~10m

    Resolution

    10mm

    10mm

    Operating Temperature

    -20?~+70?

    -20?~+70?

    Storage Temperature

    -40?~+85?

    -40?~+85?

    Material of Cover

    Aluminum Alloy

    Aluminum Alloy

    TEST CIRCUIT


    FEATURES OF OSENON ULTRASONIC SENSOR

    1, Small size and light-weight

    2, High sensitivity and high sound pressure

    3, Low power consumption

    4, High reliability

    NOTICE IN USE AND STORAGE

    1, Please do not apply D.C.voltage for ultrasonic sensors to avoid migration.

    2, Because the sensors have potential direction, please pay attention to its installation location.

    3, To ensure reliability and long service life, do not use the sensors where temperature is higher than the rated.

    4, Can not use the sensors in a vacuum zone or hazardous areas.

    5, Do not use in a steam zone, the area of the atmosphere produce uneven temperature gradient will lead to measurement error.

    6, The products should not be used or stored in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. Store the products in the room where is normal temperature and humidity, and avoid the sunlight, sudden changes in temperature and humidity. It may cause of failure or malfunction in such conditions.

    7, If you will apply to non-standard frequency and other special conditions, please inform us the specific work conditions and the circuit you need, in order to make sensors to meet your specific requirements.

    STATEMENTS

    1, No OSENON products should be used or sold for use in the design, utilization, maintenance, operation or contribution to any weapons such as nuclear, chemical or biological weapons or missiles etc.

    2, Please contact our sales representatives or product engineers before using the product in this catalog for the applications listed below, which require especially high reliability for the prevention of defects which might directly damage a third party’s life, body or property:

    ? Aircraft equipment ? Aerospace equipment ? Undersea equipment ? Power plant equipment ? Medical equipment ? Transportation equipment(vehicles, trains, ships, etc.) ? Traffic signal equipment ? Disaster prevention/ crime prevention equipment ? Data-processing equipment ? Application of similar complexity and/or reliability requirements to the applications listed above.

    3, OSENON technical team constantly improve the technology, we reserve the right to change the appearance or product specifications without notice. Please pay attention to OSENON's website for the latest news.